Mikrotron MC132x Especificaciones Pagina 21

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 45
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 20
Configuration MC132x Users Manual Rev. 0.23
21
6.5.4 Address of the last pixel of a line
Register r4 defines the horizontal end position of the ROI (region of interest ) within the sensor size. It’s
the rightmost pixel. The value is the pixel address divided by ten.
Command: :r5<x
2
x
1
x
0
> <x
2
x
1
x
0
> ... Range 000h ...07fh
Response: ACK if enabled by separate command :A<n>
Example: :r505f = 95 (dec) * 10 Ö line end at pixel 790 (dec)
Calculation of the value of r5: Value of r5 = Pixel-Nr./10
Calculation of horizontal size: (r5 – r4 + 1) * 10
e.g.: r4 = 010, r5=04f (95 - 32 + 1) * 10 = 640 pixel per line
L
The difference r5 - r4 must be in the range: 0 r5-r4 7fh .
6.5.5 Tracking
For rapid window movement even at slow baud rates a short command is provided..
command: :t<n>,<m>
<m> = X-position in pixel/10,
range 00h ...07fh
<n> = Y-position in lines / 4,
range 00h ...0ffh
Response: ACK if enabled by separate command :A<n>
6.6 Clock selection
The MC132x is equipped with a 2-channel programmable clock synthesizer. One channel controls clock
frequency of the sensor (sensorclock, F
sens
), the other controls the frequency of the pixel clock (pixel-
clock, F
pix
). These independent clocks allow an always optimal ratio depending on the product of
(image size x image frequency) and the data rate on the output.
As the sensor outputs 10 pixel per clock a sensor clock of 6.6MHz could be chosen. Because the sensor
can run up to a clock frequency of 66 MHz only 1/10 of the sensors possible speed would be used. To
make use of the maximum sensor clock and maintaining the maximum data rate on the output, just 120
(1280/10 rounded to steps of 10) from the possible 1280 pixel per line can be selected.
Therefore the ratio of F
sens
and F
pix
depends on the selected line length:
F
sens
<= (F
pix
1280) / (5 line length)
or if 100 pixel line length is chosen:
F
sens
= (33 1280) / (5 100) = 70,4 MHz
As this exceeds the maximum sensor clock frequency, F
sens
is chosen as 66 MHz and F
pix
as 33 MHz.
Vista de pagina 20