Mikrotron MC132x Especificaciones Pagina 14

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 45
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 13
Configuration MC132x Users Manual Rev. 0.22
6.2.2 Read identifier
The identifier offer information about the camera type and camera functions. It consists of 8 bytes,
which are delivered as 16 ascii characters.
Command: :V
Response (e.g.): 1324000003040303
definition of additional functions or features, 4 bytes
reserved bytes
camera type, e.g. 1324 = MC1324
Definition of functions or features: not yet used
6.2.3 Read camera settings
The actual camera settings can be read out. The answer are the values of all camera registers.
Command: :w Output as hexadecimal digits
(44 Bytes)
:W Output as ASCII-String
Example for ":w" (output as hex digits, 44 Databytes + CR + LF):
6d6448c66500650061008541898c0000
03f f03f f0000007f 0030000000000000
000000000000000000000000
CR+LF
Example for ":W" (output as ASCII string, 91 Bytes total, 88 databytes, 1x CR preceding the databytes,
1x CR after 32 ASCII-characters and 1x CR after 64 ASCII- characters):
6d6448c66500650061008541898c0000
03f f03f f0000007f 0030000000000000
CR
000000000000000000000000
Assignment of data to camera parameters:
6d6448c665006500 61008541898c 0000
03f f03f f0000007f 0030000000000000
analog settings
Codes for pixel-
and Sensorclock
000000000000000000000000
image size & position
transmitted bytes:
A1 A2 A3 A4 A5 A6 A7 A8 Sa1 Sa2 Sa3 Sb1 Sb2 Sb3
R1h R1l ... R15h R15l
A1...A8 analog settings
Sa1 Sa2 Sa3 3 Bytes frequency codes of pixelclock (see 6.7)
Sb1 Sb2 Sb3 3 Byte frequency codes for sensorclock (see 6.7)
R1…R15 image size & position
R1h ... high Byte Register1
Abb. description hex. Code
CR carriage return 0d
LF line feed 0a
R1l ... low Byte Register1
... CR+LF (0dh + 0ah)
14
Vista de pagina 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 44 45

Comentarios a estos manuales

Sin comentarios