Firmware EoSens GE Camera Manual
8.3 Firmware update procedure
Before you disable the loaded firmware please ensure that you have an adequate application
firmware version to load (e.g. EoSens….A101.ibf for application firmware, EoSens…F101.ibf
for FPGA firmware).
After this command the camera may not be able to deliver any images,
load/send/store register or profile data. The status led of the camera will turn
to red.
YOU CAN NOT UNDO THIS COMMAND.
Start MC Control Tool and select “EoSens” camera. Wait until the info screen displays
serial no. and firmware.
Select in menu “Tools” “Update microcontroller firmware” or “Update FPGA firmware”
Choose file (e.g. MC1364M626A101.ibf for microcontroller or MC136xM651F101.ibf for
FPGA) and open it. The file transfer will start immediately. While loading the LED will
blink red
Download of *.ibf file via serial link takes app. 1 - 5 min depending on the used
baudrate. There should be no loss of power or communication during this time!
Wait until file transfer has finished and the status led stays on. If the upload of the file
was successful, the led will turn to green, otherwise it will be red.
Verify version in “EoSens” info screen. The new firmware version will be displayed. If
the version is identical to the expected the camera is ready to use for capturing images.