Mikrotron EOSENS GE CAMERA Especificaciones Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 37
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
Hardware EoSens GE Camera Manual
3 Hardware
3.1 GigE Vision
®
interface
GigE Vision
®
is designed for digital cameras in machine vision applications. This interface can
transfer data at a rate of 110 Mbytes/sec.
The GigE Vision
®
chipset and software is designed and implemented by Pleora Tech. Inc. the
leading supplier of GigE Vision technology. Please refer to the PT1000 documentation for
further information.
3.2 Power supply
The camera needs a DC supply voltage between 8 … 24V at a power consumption of 6 Watt
max.
See also Connector pinning.
Before applying power to the camera we strongly recommend to verify the used
pins of the power connector, the polarity (+/-) of the leads and the supply voltage.
The camera may only be used with a supply voltage according to the camera spe-
cification. Connecting a lower or higher supply voltage, AC voltage, reversal
polarity or using wrong pins of the power connector may damage the camera. If
doing so, the warranty will expire immediately.
3.3 Status LED
A dual color LED on the camera backplane shows the operating condition of the EoSens.
LED orange... The EoSens is configuring the internal FPGA. No other activity is possible.
LED green... The EoSens is fully operational.
LED off... If LED is off, despite the camera is powered, data is stored to the internal
EEPROM. No other activity is possible.
LED red... The microcontroller detected a wrong checksum or the FPGA could not be
loaded because of wrong FPGA configuration data. The camera is not
functional. Try to reload configuration data.
LED red blinking... Data is loaded to microcontroller or FPGA from the PC or the camera
verifies the checksum. No other activity is possible.